| 000 | 02921cam a2200397Ii 4500 | ||
|---|---|---|---|
| 999 |
_c96739 _d96739 _x1 |
||
| 001 | 96739 | ||
| 003 | ES-MaUEC | ||
| 005 | 20230102112808.0 | ||
| 006 | m o d | ||
| 007 | cr cnu|||unuuu | ||
| 008 | 171208s2017 nyu ob 000 0 eng d | ||
| 020 |
_a1493974416 _q(electronic bk.) |
||
| 020 |
_a9781493974412 _q(electronic bk.) |
||
| 020 | _z1493974408 | ||
| 020 |
_z9781493974405 _q(print) |
||
| 040 |
_aGW5XE _beng _erda _epn _cGW5XE _dN$T _dEBLCP _dYDX _dOCLCF _dUAB _dDKU _dES-MaUEC _bspa |
||
| 050 | 4 |
_aQP124 _b2017 EB |
|
| 100 | 1 |
_aHopkins, Susan R. _eautor _9677363 |
|
| 245 | 1 | 4 |
_aThe multiple inert gas elimination technique (MIGET) _cSusan R. Hopkins, Peter D. Wagner. |
| 264 | 1 |
_aNew York, NY _bSpringer International Publishing _c2017 |
|
| 300 |
_a1 recurso en línea (xiii, 329 páginas) _bilustraciones (algunas a color) |
||
| 336 |
_aTexto _btxt _2rdacontent |
||
| 337 |
_aelectrónico _bc _2rdamedia |
||
| 338 |
_arecurso electrónico _bcr _2rdacarrier |
||
| 490 | 0 | _aMethods in physiology | |
| 500 | _a | ||
| 504 | _aIncluye referencias bibliográficas | ||
| 520 | 3 | _aThis is the first book to bring together the history, theory, mathematical approach, measurement details and limitations of the Multiple Inert Gas Elimination Technique (MIGET) and a summary of the global literature on its application in health and disease over the last 40 years. Up to the early 1970's, and despite substantial research carried out by leaders in respiratory physiology, it was not possible to measure the most important and most complex component of gas exchange in the lung: ventilation/perfusion (VA/Q) heterogeneity. Building on that earlier research, MIGET was developed to overcome this large gap in our understanding of the most important function of the lung. Just as CT and MRI make use of multiple, simultaneous imaging views to reconstruct the underlying anatomy spatially, MIGET uses the simultaneous exchange of six inert gases with differing blood solubility to reconstruct the functional distribution of VA/Q ratios. While the basic physiological principle of MIGET is straightforward, using inert gas exchange data to construct the VA/Q distribution requires complicated mathematics along with the ability to simultaneously measure the exchange of six foreign gases present in just parts per million or less. This unique book is a valuable resource for anyone interested in how the lung works. | |
| 588 | 0 | _aOnline resource; title from PDF title page (SpringerLink, viewed December 8, 2017). | |
| 988 | _aEBOOK, EBSPRINGER_2017 | ||
| 650 | 7 |
_aNeumología _2embne _9670074 |
|
| 700 |
_aWagner, Peter D. _q(Peter D.), _eautor _996565 |
||
| 856 | 4 | 0 |
_uhttps://go.openathens.net/redirector/universidadeuropea.es?url=http://link.springer.com/10.1007/978-1-4939-7441-2 _zAcceso a este recurso digital (usuarios Universidad Europea de Madrid) |
| 942 |
_2lcc _cLE |
||
| 998 |
_b02/2018 _dz _e- _zSI |
||