| 000 | 05240cam a2200469Ii 4500 | ||
|---|---|---|---|
| 001 | 96305 | ||
| 003 | ES-MaUEC | ||
| 005 | 20230102112748.0 | ||
| 006 | m o d | ||
| 007 | cr |n||||||||| | ||
| 008 | 170707s2017 si a ob 001 0 eng d | ||
| 020 |
_a9789811046360 _q(electronic bk.) |
||
| 020 |
_a9811046360 _q(electronic bk.) |
||
| 020 | _z9789811046353 | ||
| 020 | _z9811046352 | ||
| 040 |
_aN$T _cN$T _dN$T _dEBLCP _dGW5XE _dYDX _dOCLCF _dNJR _dUAB _dESU _dAZU _dUPM _dCOO _dOCLCQ _dMERER _dVT2 _dOCLCQ _dIOG _dES-MaUEC _bspa |
||
| 050 | 4 |
_aRC78.7.D53 _b2017 EB |
|
| 100 | 1 |
_aGunjan, Vinit Kumar, _eautor |
|
| 245 | 1 | 0 |
_aComputational methods in molecular imaging technologies _cVinit Kumar Gunjan, Fahimuddin Shaik, C. Venkatesh, M. Amarnath. |
| 264 | 1 |
_aSingapore _bSpringer _c[2017] |
|
| 300 | _a1 recurso en línea | ||
| 336 |
_aTexto _btxt _2rdacontent |
||
| 337 |
_aelectrónico _bc _2rdamedia |
||
| 338 |
_arecurso electrónico _bcr _2rdacarrier |
||
| 347 |
_atext file _bPDF |
||
| 490 | 0 | _aSpringerBriefs in applied sciences and technology. Forensic and medical bioinformatics | |
| 500 |
_aSpringerLink _bSpringer Engineering eBooks 2017 English+International |
||
| 504 | _aIncluye referencias bibliográficas | ||
| 505 | 0 | _aPreface; Acknowledgements; Contents; About the Authors; Abstract; 1 Introduction; 1.1 Introduction to Medical Imaging; 1.2 Medical Imaging Overview; 1.3 Molecular Imaging and Its Modalities; 1.4 Medical Image Reconstruction; 1.5 Types of Image Reconstruction; 2 Artifacts Correction in MRI Images; 2.1 Existing Methods; 2.1.1 Disadvantages of Ultra-echo Time Imaging (UTE); 2.1.2 Disadvantages of Sweep Imaging with Fourier Transform; 2.1.3 Disadvantages of Water- and Fat-suppressed Proton Projection MRI; 2.1.4 Disadvantages of ZTE Imaging Without Excitation Profile; 2.2 Implemented Method. | |
| 505 | 8 | _a2.3 Process Diagram2.4 Model as an Inverse Problem; 2.5 NUFFT Operator; 2.5.1 Features of NUFFT; 2.5.2 Non-uniform FFT Algorithm; 2.6 Quadratic Phase-Modulated RF Pulse Excitation; 2.6.1 Hard RF Phase Modulation; 2.7 Excitation Profile Measurement; 2.8 Pointwise Encoding Time Reduction with Radial Acquisition (PETRA); 2.9 Iterative Partial K-Space Reconstruction; 2.10 Processing of Project; 2.11 Flow Diagram; 3 Spiral Cone-Beam CT Reconstruction; 3.1 CT Reconstruction Using the Medical Phantom Image; 3.1.1 Assessment of Image Quality of the CT Medical Phantom Image Before Reconstruction. | |
| 505 | 8 | _a3.1.2 Assesment of the Image Quality of Cone-Beam Phantom After Image Reconstruction3.2 CT Reconstruction of the Hand Section of the Human Body; 3.2.1 Assesment of the Image Quality of CT Hand Section Before Reconstruction; 3.2.2 Assesment of the Image Quality of Cone-Beam CT Hand Section After Reconstruction; 3.3 CT Reconstruction of the Head Section of the Human Body; 3.3.1 Assesment of the Image Quality of the CT Head Section Before Reconstruction; 3.3.2 Assesment of the Image Quality of the Cone-Beam CT Head Section After Reconstruction; 3.4 Quantization of the Artifacts. | |
| 505 | 8 | _a3.4.1 Assessment of Image Resolution and Noise Quantization of the Artifacts3.4.1.1 Factors Affecting the Assessment of Image Resolution and Noise Quantization of the Artifacts; 3.4.1.2 Image Quality Metrics; 3.4.1.3 Computational Efficiency Measurement; 4 Visual Quality Improvement of CT Image Reconstruction with Quantitative Measures; 4.1 Existing System; 4.1.1 Background; 4.1.2 Criterion for Filtering Edge Information; 4.2 Proposed Algorithms; 4.2.1 Model Specification; 4.2.2 Boundary-Edge Correspondence; 4.2.3 Local Intensity Clustering Property; 4.2.4 Energy Formulation. | |
| 505 | 8 | _a4.2.5 Multiphase Level Set Formulation4.3 Block Diagram; 4.4 Back Projection; 4.5 Filtered Back Projection (FBP) Reconstruction; 4.6 Discrete Direct Back Projection; 4.7 Data Acquisition; 4.8 Iterative Reconstruction Algorithm; 4.9 Histogram Processing; 4.10 Bias Field; 4.11 Experimental Findings; 4.11.1 Assesment of the Image Statistics of Before Image Reconstruction of CT Knee Bone; 4.11.2 Assesment of the Image Statistics of After Image Reconstruction of CT Knee Bone; 4.12 Computational Efficiency Comparison; Bibliography. | |
| 520 | 3 | _aThis book highlights the experimental investigations that have been carried out on magnetic resonance imaging and computed tomography (MRI & CT) images using state-of-the-art Computational Image processing techniques, and tabulates the statistical values wherever necessary. In a very simple and straightforward way, it explains how image processing methods are used to improve the quality of medical images and facilitate analysis. It offers a valuable resource for researchers, engineers, medical doctors and bioinformatics experts alike. | |
| 650 | 7 |
_aBioinformática _2embne _0(OCoLC)fst00871990 _0 _9160489 |
|
| 700 | 1 |
_aAmarnath, M., _eautor |
|
| 700 | 1 |
_aShaik, Fahimuddin, _eautor _9100846 |
|
| 700 | 1 |
_aVenkatesh, Chethan, _eautor |
|
| 856 | 4 | 0 |
_uhttps://go.openathens.net/redirector/universidadeuropea.es?url=http://link.springer.com/10.1007/978-981-10-4636-0 _zAcceso a este recurso digital (usuarios Universidad Europea de Madrid) |
| 988 | _aEBOOK, asignarmaterias, EBSPRINGER_2017D | ||
| 998 |
_b02/2018 _dz _e- _zSI |
||
| 999 |
_c96305 _d96305 _x1 |
||