| 000 | 05434cam a2200481Ii 4500 | ||
|---|---|---|---|
| 999 |
_c94972 _d94972 |
||
| 001 | 94972 | ||
| 003 | ES-MaUEC | ||
| 005 | 20230102112641.0 | ||
| 006 | m o d | ||
| 007 | cr cnu|||unuuu | ||
| 008 | 161202s2017 si ob 000 0 eng d | ||
| 020 | _a9789811029226 | ||
| 020 |
_a9789811029233 _q(electronic bk.) |
||
| 020 | _a9811029229 | ||
| 020 |
_a9811029237 _q(electronic bk.) |
||
| 020 |
_z9789811029226 _q(print) |
||
| 035 |
_a(OCoLC)964698708 _z(OCoLC)965145679 _z(OCoLC)974651069 _z(OCoLC)981107772 _z(OCoLC)1005780056 |
||
| 040 |
_aN$T _cN$T _dIDEBK _dEBLCP _dGW5XE _dN$T _dIDB _dAZU _dUAB _dCOO _dYDX _dUPM _dVT2 _dUWO _dIOG _dOCLCO _dMERER _dOCLCO _dESU _dZ5A _dOCLCO _dJBG _dIAD _dOCLCO _dICW _dOCLCO _dICN _dOCLCO _dMERUC _dOTZ _dOCLCQ _dOCLCO _dU3W _dOCLCO _dOCLCA _dES-MaUEC _bspa |
||
| 050 | 4 |
_aRA969.4 _bX894 2017 EB |
|
| 100 | 1 |
_aXu, Zhonglin, _eautor _9670307 |
|
| 245 | 1 | 0 |
_aDynamic isolation technologies in negative pressure isolation wards _cZhonglin Xu, Bin Zhou. |
| 264 | 1 |
_aSingapore _bSpringer _c[2017] |
|
| 300 | _a1 recurso en línea | ||
| 336 |
_aTexto _btxt _2rdacontent |
||
| 337 |
_aelectrónico _bc _2rdamedia |
||
| 338 |
_arecurso electrónico _bcr _2rdacarrier |
||
| 347 |
_atext file _bPDF _2rda |
||
| 500 | _aSpringerLink | ||
| 504 | _aIncluye referencias bibliográficas | ||
| 505 | 0 | _aPreface; Contents; 1 Importance of Negative Pressure Wards; 1.1 The Disaster at the Beginning of the Century; 1.2 Severity of Airborne Infection; 1.3 Requirement for Negative Pressure Ward; References; 2 Three Misunderstandings for Design of Negative Pressure Ward; 2.1 About High Negative Pressure; 2.1.1 Effect of Pressure Difference; 2.1.2 Ability to Control Pollution Dispersion by Pressure Difference; 2.2 About Airproof Gate; 2.2.1 Effect of Entrainment by Door; 2.2.2 Dynamic Characteristic of Door [1]; 2.2.3 Effect of Entrainment by Occupant. | |
| 505 | 8 | _a2.2.4 Effect of Temperature Difference Between Indoors and Outdoors2.2.5 Balance Equation of Air Change Rate with Convective Flow by Temperature Difference; 2.2.6 Relationship Between Temperature Difference and Pollutant Exchange Rate; 2.3 About Full Fresh Air; 2.3.1 Outline; 2.3.2 HEPA Filter and Virus Particles; References; 3 Principle and Technology of Dynamic Isolation; 3.1 Proper Pressure Difference for Isolation; 3.1.1 Physical Significance of Pressure Difference; 3.1.2 Determination of Pressure Difference; 3.2 Buffer Room for Isolation; 3.2.1 Mode of Buffer Room. | |
| 505 | 8 | _a3.2.2 Isolation Coefficient of Buffer Room3.2.3 Influencing Factors for Performance of Buffer Room; 3.2.4 Experimental Validation; 3.2.5 Door of Buffer Room; 3.3 Airflow Isolation in Mainstream Area; 3.3.1 Concept of Mainstream Area; 3.3.2 Function of Mainstream Area; 3.4 Application of Self-circulation Air Through HEPA Filter; 3.4.1 Application Principle of Circulation Air; 3.4.2 Function of HEPA Filter; 3.4.3 Experimental Validation for Application of HEPA Filter with Circulation Air; References; 4 Air Distribution Design in Negative Pressure Isolation Ward. | |
| 505 | 8 | _a4.1 Fundamental Principle of Air Distribution in Negative Pressure Isolation Ward4.2 Velocity Field Near Return Air Opening; 4.3 Velocity Decay Near Air Supply Outlet; 4.4 The Following Speed and the Deposition Velocity; 4.5 Composition of Velocities and Vortex [9]; 4.6 Position of Air Supply, Exhaust and Return Outlets in Isolation Ward; 4.6.1 Fundamental Principle; 4.6.2 Related Assessment Index; 4.6.3 Results from Numerical Simulation [10, 12]; 4.6.4 Experimental Validation on Performance of Opening Position; References; 5 Calculation of Air Change Rate; 5.1 Outline. | |
| 505 | 8 | _a5.2 Two System Modes of Isolation Ward5.2.1 Circulation Air System; 5.2.2 Full Fresh Air System; 5.3 Determination of Bacterial Generation Rate Indoors; 5.3.1 Bacterial Generation Rate from Ordinary Patients; 5.3.2 Analysis of Bacterial Generation Rate from Respiratory System; 5.4 Determination of Bacterial Concentration Standard Indoors; 5.4.1 Outline; 5.4.2 Standard; 5.5 Calculation of Air Change Rate; 5.5.1 Calculation Based on the Minimum Airborne Droplet Nuclei with Diameter 0.075 æm. | |
| 520 | 3 | _aThis book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas. | |
| 588 | 0 | _aOnline resource; title from PDF title page (SpringerLink, viewed December 28, 2016). | |
| 988 | _aEBOOK, EBSPRINGER_2017B | ||
| 650 | 7 |
_2embne _aAire _xCalidad _9406492 |
|
| 700 | 1 |
_aZhou, Bin, _eautor |
|
| 856 | 4 | 0 |
_uhttps://go.openathens.net/redirector/universidadeuropea.es?url=http://link.springer.com/10.1007/978-981-10-2923-3 _zAcceso a este recurso digital (usuarios Universidad Europea de Madrid) |
| 942 |
_2lcc _cLE |
||
| 998 |
_b02/2018 _dz _e- _zSI |
||