000 05434cam a2200481Ii 4500
999 _c94972
_d94972
001 94972
003 ES-MaUEC
005 20230102112641.0
006 m o d
007 cr cnu|||unuuu
008 161202s2017 si ob 000 0 eng d
020 _a9789811029226
020 _a9789811029233
_q(electronic bk.)
020 _a9811029229
020 _a9811029237
_q(electronic bk.)
020 _z9789811029226
_q(print)
035 _a(OCoLC)964698708
_z(OCoLC)965145679
_z(OCoLC)974651069
_z(OCoLC)981107772
_z(OCoLC)1005780056
040 _aN$T
_cN$T
_dIDEBK
_dEBLCP
_dGW5XE
_dN$T
_dIDB
_dAZU
_dUAB
_dCOO
_dYDX
_dUPM
_dVT2
_dUWO
_dIOG
_dOCLCO
_dMERER
_dOCLCO
_dESU
_dZ5A
_dOCLCO
_dJBG
_dIAD
_dOCLCO
_dICW
_dOCLCO
_dICN
_dOCLCO
_dMERUC
_dOTZ
_dOCLCQ
_dOCLCO
_dU3W
_dOCLCO
_dOCLCA
_dES-MaUEC
_bspa
050 4 _aRA969.4
_bX894 2017 EB
100 1 _aXu, Zhonglin,
_eautor
_9670307
245 1 0 _aDynamic isolation technologies in negative pressure isolation wards
_cZhonglin Xu, Bin Zhou.
264 1 _aSingapore
_bSpringer
_c[2017]
300 _a1 recurso en línea
336 _aTexto
_btxt
_2rdacontent
337 _aelectrónico
_bc
_2rdamedia
338 _arecurso electrónico
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aSpringerLink
504 _aIncluye referencias bibliográficas
505 0 _aPreface; Contents; 1 Importance of Negative Pressure Wards; 1.1 The Disaster at the Beginning of the Century; 1.2 Severity of Airborne Infection; 1.3 Requirement for Negative Pressure Ward; References; 2 Three Misunderstandings for Design of Negative Pressure Ward; 2.1 About High Negative Pressure; 2.1.1 Effect of Pressure Difference; 2.1.2 Ability to Control Pollution Dispersion by Pressure Difference; 2.2 About Airproof Gate; 2.2.1 Effect of Entrainment by Door; 2.2.2 Dynamic Characteristic of Door [1]; 2.2.3 Effect of Entrainment by Occupant.
505 8 _a2.2.4 Effect of Temperature Difference Between Indoors and Outdoors2.2.5 Balance Equation of Air Change Rate with Convective Flow by Temperature Difference; 2.2.6 Relationship Between Temperature Difference and Pollutant Exchange Rate; 2.3 About Full Fresh Air; 2.3.1 Outline; 2.3.2 HEPA Filter and Virus Particles; References; 3 Principle and Technology of Dynamic Isolation; 3.1 Proper Pressure Difference for Isolation; 3.1.1 Physical Significance of Pressure Difference; 3.1.2 Determination of Pressure Difference; 3.2 Buffer Room for Isolation; 3.2.1 Mode of Buffer Room.
505 8 _a3.2.2 Isolation Coefficient of Buffer Room3.2.3 Influencing Factors for Performance of Buffer Room; 3.2.4 Experimental Validation; 3.2.5 Door of Buffer Room; 3.3 Airflow Isolation in Mainstream Area; 3.3.1 Concept of Mainstream Area; 3.3.2 Function of Mainstream Area; 3.4 Application of Self-circulation Air Through HEPA Filter; 3.4.1 Application Principle of Circulation Air; 3.4.2 Function of HEPA Filter; 3.4.3 Experimental Validation for Application of HEPA Filter with Circulation Air; References; 4 Air Distribution Design in Negative Pressure Isolation Ward.
505 8 _a4.1 Fundamental Principle of Air Distribution in Negative Pressure Isolation Ward4.2 Velocity Field Near Return Air Opening; 4.3 Velocity Decay Near Air Supply Outlet; 4.4 The Following Speed and the Deposition Velocity; 4.5 Composition of Velocities and Vortex [9]; 4.6 Position of Air Supply, Exhaust and Return Outlets in Isolation Ward; 4.6.1 Fundamental Principle; 4.6.2 Related Assessment Index; 4.6.3 Results from Numerical Simulation [10, 12]; 4.6.4 Experimental Validation on Performance of Opening Position; References; 5 Calculation of Air Change Rate; 5.1 Outline.
505 8 _a5.2 Two System Modes of Isolation Ward5.2.1 Circulation Air System; 5.2.2 Full Fresh Air System; 5.3 Determination of Bacterial Generation Rate Indoors; 5.3.1 Bacterial Generation Rate from Ordinary Patients; 5.3.2 Analysis of Bacterial Generation Rate from Respiratory System; 5.4 Determination of Bacterial Concentration Standard Indoors; 5.4.1 Outline; 5.4.2 Standard; 5.5 Calculation of Air Change Rate; 5.5.1 Calculation Based on the Minimum Airborne Droplet Nuclei with Diameter 0.075 æm.
520 3 _aThis book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
588 0 _aOnline resource; title from PDF title page (SpringerLink, viewed December 28, 2016).
988 _aEBOOK, EBSPRINGER_2017B
650 7 _2embne
_aAire
_xCalidad
_9406492
700 1 _aZhou, Bin,
_eautor
856 4 0 _uhttps://go.openathens.net/redirector/universidadeuropea.es?url=http://link.springer.com/10.1007/978-981-10-2923-3
_zAcceso a este recurso digital (usuarios Universidad Europea de Madrid)
942 _2lcc
_cLE
998 _b02/2018
_dz
_e-
_zSI