000 05544cam a2200457Ma 4500
988 _aSpringer_Medicine_2017
999 _c94954
_d94954
_x1
001 94954
003 ES-MaUEC
005 20230102112640.0
006 m o d
007 cr |n|||||||||
008 161130s2017 sz ob 001 0 eng d
020 _a3319418769
_q(electronic bk.)
020 _a9783319418766
_q(electronic bk.)
020 _z3319418742
_q(print)
020 _z9783319418742
_q(print)
035 _a(OCoLC)964599583
_z(OCoLC)964931370
_z(OCoLC)974651463
_z(OCoLC)981111252
_z(OCoLC)1005757283
040 _aYDX
_cYDX
_dN$T
_dIDEBK
_dEBLCP
_dGW5XE
_dOCLCF
_dN$T
_dAZU
_dUAB
_dCOO
_dOCLCQ
_dUPM
_dIOG
_dVT2
_dESU
_dJBG
_dIAD
_dICW
_dICN
_dOTZ
_dOHI
_dOCLCQ
_dMERER
_dOCLCQ
_dU3W
_dES-MaUEC
_bspa
050 4 _aRE986
_b2017 EB
245 0 0 _aArtificial vision :
_ba clinical guide
_cVeit Peter Gabel, editor
264 1 _aCham, Switzerland
_bSpringer
_c2017
300 _a1 recurso en línea
336 _aTexto
_btxt
_2rdacontent
337 _aelectrónico
_bc
_2rdamedia
338 _arecurso electrónico
_bcr
_2rdacarrier
347 _atext file
_bPDF
_2rda
500 _aIncluye índice
500 _aSpringerLink
505 0 _aForeword; Preface; Contents; Contributors; Part I: Introduction or Principles of Functional Assessment; Chapter 1: Assessing Patient Suitability and Outcome Measures in Vision Restoration Trials; Developing an International Consensus on the Measurement and Reporting of Patient Outcomes: The Harmonization of Outcomes and Vision Endpoints in Vision Restoration Trials (HOVER) Taskforce; Advice to the Practicing Ophthalmologist: How to Test and Advise Patients Interested in Restoration Therapies at Present; References; Chapter 2: Functional Assessment of Artificial Vision; Introduction.
505 8 _aApplication to Prosthetic VisionReferences; Chapter 4: Prospects and Limitations of Spatial Resolution; Which Spatial Resolution Should Be Targeted by Visual Prosthesis?; Reading; Visuo-motor Coordination; Whole Body Mobility; Synthesis; From Theory to Reality; Conclusion and Final Thoughts; References; Part II: Retinal Approaches; Chapter 5: Argus® II Retinal Prosthesis System; Principal Idea; Indication; Technical Description; Surgical Methods; Full Clinical Study; Device Development History; Argus I; Argus® II; Patients; Adverse Events; Functional Ouctomes.
505 8 _aStandardisation Forced Choice Testing; Efficient Testing Algorithms and Scoring Methods; Psychometric Properties of Functional Vision Tests; Basic Visual Function Tests; Light Perception; Spatial Resolution; Activities of Daily Living; Object Recognition; Picture Recognition; Navigation Ability; Multimodal Sensory Integration; Conclusions; References; Chapter 3: Patient-Reported Outcomes (PRO) for Prosthetic Vision; Introduction; Basic Psychometric Concepts; Rasch Analysis; Precision of Item and Person Measure Estimates; Subscales, Visual Domains, Visual Aspects.
505 8 _aThe Boston Retinal Implant Wireless Power and Data; Custom Integrated Circuit Design; Microfabricated Thin-Film Multi-electrode Array; Hermetic Retinal Implant Packaging; Current Status and Future Directions; References; Chapter 8: Pixium Vision: First Clinical Results and Innovative Developments; Introduction; IRISTM System Description; External Components; Implant; Surgical Method; The Clinical Trial; Acute Clinical Trail; Chronic Clinical Trial; Future Technologies; Conclusions; References.
505 8 _aVisual Function Orientation and Mobilitity Tests; Activities of Daily Living; Future Directions; References; Chapter 6: The Subretinal Implant ALPHA: Implantation and Functional Results; Introduction: Principal Concept and Steps of Development; Technical Description; Indication for Certain Forms of Blindness; Who Can Benefit from the Subretinal Implant to What Extent?; Surgical Procedure for Subretinal Implants; Replacement of Implants; Clinical Study Results; Safety; Conclusion; References; Chapter 7: The Boston Retinal Implant; Overview; Background; Device Requirements.
520 3 _aThis book presents and analyses the most recent research dedicated to restoring vision in individuals who are severely impaired or blind from retinal disease or injury. It is written by the leading groups worldwide who are at the forefront of developing artificial vision. The book begins by discussing the difficulties in comparing and interpreting functional results in the area of very low vision and the principal prospects and limitations of spatial resolution with artificial tools. Further on, chapters are included by researchers who stimulate the surface or the pigment epithelial side of the retina and by experts who work on stimulating the optic nerve, the lateral geniculate body and the superficial layers of the visual cortex. Artificial Vision: A Clinical Guide collates the most recent work of key artificial vision research groups to explain in a comparable and stringent order their varying approaches, the clinical or preclinical outcomes and their achievements during the last years. Senior ophthalmic fellows and academic practitioners will find this guide to be an indispensable resource for understanding the current status of artificial vision.
588 0 _aVersión impresa
650 7 _aPrótesis oculares
_2embne
_9152283
700 1 _aGabel, V.-P.
_q(Veit-Peter),
_eeditor literario
856 4 0 _uhttp://link.springer.com
_zAcceso a este recurso digital (usuarios Universidad Europea de Madrid)
942 _2lcc
_cLE
998 _b02/2018
_dz
_e-
_zSI