| 000 | 03364nam a2200445 i 4500 | ||
|---|---|---|---|
| 999 |
_c362896 _d362896 _x1 |
||
| 001 | 362896 | ||
| 003 | ES-MaUEC | ||
| 005 | 20230102121631.0 | ||
| 006 | a||||fo|||| 00| 0 | ||
| 007 | cr nn 008mamaa | ||
| 008 | 210614s2021 sz | o |||| 0|eng d | ||
| 020 | _a9783030761790 | ||
| 024 | 7 |
_a10.1007/978-3-030-76179-0 _2doi |
|
| 040 |
_aES-MaUEC _bspa _cES-MaUEC _dES-MaUEC |
||
| 050 | 4 |
_aTK7876 _b2021 EB |
|
| 100 | 1 |
_aJuan, Carlos G. _eautor _4aut _4http://id.loc.gov/vocabulary/relators/aut _9682438 |
|
| 245 | 1 | 0 |
_aDesigning Microwave Sensors for Glucose Concentration Detection in Aqueous and Biological Solutions : _bTowards Non-invasive Glucose Sensing _cby Carlos G. Juan |
| 250 | _aFirst edition 2021 | ||
| 264 | 1 |
_aCham _bSpringer International Publishing _c2021 |
|
| 300 |
_a1 recurso en línea (XXIII, 242 páginas) _b114 ilustraciones, 92 ilustraciones a color |
||
| 336 |
_2rdacontent _aTexto _btxt |
||
| 337 |
_2rdamedia _aelectrónico _bc |
||
| 338 |
_2rdacarrier _arecurso electrónico _bcr |
||
| 347 |
_aArchivo de texto _bPDF |
||
| 490 | 0 |
_aSpringer Theses, Recognizing Outstanding Ph.D. Research _x2190-5061 |
|
| 505 | 0 | _aIntroduction -- State of the art -- Dielectric characterization of water-glucose solutions -- Glucose concentration detection in aqueous solutions -- Glucose concentration detection in biological solutions with microwave sensors 145. | |
| 520 | _aThis book presents a comprehensive study covering the design and application of microwave sensors for glucose concentration detection, with a special focus on glucose concentration tracking in watery and biological solutions. This book is based on the idea that changes in the glucose concentration provoke variations in the dielectric permittivity of the medium. Sensors whose electrical response is sensitive to the dielectric permittivity of the surrounding media should be able to perform as glucose concentration trackers. At first, this book offers an in-depth study of the dielectric permittivity of water-glucose solutions at concentrations relevant for diabetes purposes; in turn, it presents guidelines for designing suitable microwave resonators, which are then tested in both water-glucose solutions and multi-component human blood plasma solutions for their detection ability and sensitivities. Finally, a portable version is developed and tested on a large number of individuals in a real clinical scenario. All in all, the book reports on a comprehensive study on glucose monitoring devices based on microwave sensors. It covers in depth the theoretical background, provides extensive design guidelines to maximize sensitivity, and validates a portable device for applications in clinical settings. . | ||
| 988 | _aSpringer_Medicine_2021 | ||
| 650 | 7 |
_2embne _9138714 _aMicroondas |
|
| 650 | 7 |
_2embne _9143820 _aIngeniería biomédica |
|
| 776 | 0 | 8 |
_iPrinted edition: _z9783030761783 |
| 776 | 0 | 8 |
_iPrinted edition: _z9783030761806 |
| 776 | 0 | 8 |
_iPrinted edition: _z9783030761813 |
| 856 | 4 | 0 |
_uhttps://go.openathens.net/redirector/universidadeuropea.es?url=https://doi.org/10.1007/978-3-030-76179-0 _zAcceso a este recurso digital (usuarios Universidad Europea de Madrid) |
| 942 |
_2lcc _cLE |
||
| 998 |
_b02/2022 _dz _eb _zSI |
||