000 03289nam a2200421 i 4500
999 _c122024
_d122024
_x1
001 122024
003 ES-MaUEC
005 20230102114159.0
006 a||||fo|||| 00| 0
007 cr nn nnnaamaa
008 200715s2020 si a fo |||| 0|eng d
020 _a9789811537776
024 7 _a10.1007/978-981-15-3777-6
_2doi
040 _aES-MaUEC
_bspa
_cES-MaUEC
_dES-MaUEC
050 4 _aRD598
_b2020 EB
245 0 0 _aSlender PCI :
_bExtremely Minimally Invasive Percutaneous Coronary Intervention
_cedited by Fuminobu Yoshimachi
250 _aFirst edition
264 1 _aSingapore
_bSpringer International Publishing
_c2020
300 _a1 recurso en línea (X, 219 páginas)
_b108 ilustraciones, 64 ilustraciones a color
336 _2rdacontent
_aTexto
_btxt
337 _2rdamedia
_aelectrónico
_bc
338 _2rdacarrier
_arecurso electrónico
_bcr
347 _aArchivo de texto
_bPDF
490 0 _aMedicine (SpringerNature-11650)
490 0 _aMedicine (R0) (SpringerNature-43714)
505 0 _aBrief Overview of Slender Catheter -- Evidence of Slender PCI -- TRI to dTRI -- Distal Radial Approach / Distal Transradial Intervention -- Expectation for dTRI and Slender Catheter -- Slender Catheter Back-up -- Needling and Blood Snatching of Conventional Radial Approach & Distal Radial Approach -- Reduction of Radiation Exposure and Contrast Agent -- Semi-Comfpliant and Non-Compliant Slender Catheter -- FFR with a 4Fr Wide Lumen Diagnosis Catheter -- Catheter for 3Fr Diagnosis -- Sheathless of Slender in UK -- Sheathless of Slender in JP -- Slender PCI to Bifurcation Lesion -- Slender PCI to Calcified Lesion -- Slender PCI to ACS -- Slender CTO: Antegrade approach -- Slender CTO: Retrograde approach.
520 3 _aThis book offers a valuable contribution to the field of minimally invasive coronary intervention, presenting the latest developments in slender catheters, their development and the related research findings. With the growing interest in trans-radial interventions (TRIs) and distal radial approach, "Slender PCI" has been popular in Japan. Although "Slender PCI" started with using a small diameter catheter of a 5Fr Guiding Catheter, recently it becomes a generic term for all minimally invasive catheter Interventions. "Slender PCI" not only makes less painful but also reduces exposure to radiation and contrast agents. In addition, the book highlights the distal radial approach, 5Fr guiding catheter for treating complex lesion, 4Fr guiding catheters, 3Fr diagnosis catheters. The authors share their experiences and know-how throughout, providing abundant illustrations to enhance readers' understanding.
988 _aSpringer_Medicine_2020
650 7 _2embne
_aCorazón
_xCirugía
_9174357
650 7 _2embne
_9405674
_aCirugía endoscópica
700 1 _aYoshimachi, Fuminobu
_eeditor literario
_4edt
_4http://id.loc.gov/vocabulary/relators/edt
776 0 8 _iPrinted edition:
_z9789811537769
776 0 8 _iPrinted edition:
_z9789811537783
776 0 8 _iPrinted edition:
_z9789811537790
856 4 0 _uhttps://go.openathens.net/redirector/universidadeuropea.es?url=https://doi.org/10.1007/978-981-15-3777-6
_zAcceso a este recurso digital (usuarios Universidad Europea de Madrid)
942 _2lcc
_cLE
998 _b09/2020
_dz
_eb
_zSI