Image from Google Jackets

Computational methods in molecular imaging technologies / Vinit Kumar Gunjan, Fahimuddin Shaik, C. Venkatesh, M. Amarnath.

By: Gunjan, Vinit Kumar,, autor
Contributor(s): Amarnath, M.,, autor | Shaik, Fahimuddin,, autor | Venkatesh, Chethan,, autor
Material type: materialTypeLabelE-bookSeries: (SpringerBriefs in applied sciences and technology. Forensic and medical bioinformatics).Publisher: Singapore : Springer, [2017]Description: 1 recurso en línea.ISBN: 9789811046360; 9811046360.Subject: BioinformáticaOnline resources: Acceso a este recurso digital (usuarios Universidad Europea de Madrid)Digital Resources
Contents:
Preface; Acknowledgements; Contents; About the Authors; Abstract; 1 Introduction; 1.1 Introduction to Medical Imaging; 1.2 Medical Imaging Overview; 1.3 Molecular Imaging and Its Modalities; 1.4 Medical Image Reconstruction; 1.5 Types of Image Reconstruction; 2 Artifacts Correction in MRI Images; 2.1 Existing Methods; 2.1.1 Disadvantages of Ultra-echo Time Imaging (UTE); 2.1.2 Disadvantages of Sweep Imaging with Fourier Transform; 2.1.3 Disadvantages of Water- and Fat-suppressed Proton Projection MRI; 2.1.4 Disadvantages of ZTE Imaging Without Excitation Profile; 2.2 Implemented Method.
2.3 Process Diagram2.4 Model as an Inverse Problem; 2.5 NUFFT Operator; 2.5.1 Features of NUFFT; 2.5.2 Non-uniform FFT Algorithm; 2.6 Quadratic Phase-Modulated RF Pulse Excitation; 2.6.1 Hard RF Phase Modulation; 2.7 Excitation Profile Measurement; 2.8 Pointwise Encoding Time Reduction with Radial Acquisition (PETRA); 2.9 Iterative Partial K-Space Reconstruction; 2.10 Processing of Project; 2.11 Flow Diagram; 3 Spiral Cone-Beam CT Reconstruction; 3.1 CT Reconstruction Using the Medical Phantom Image; 3.1.1 Assessment of Image Quality of the CT Medical Phantom Image Before Reconstruction.
3.1.2 Assesment of the Image Quality of Cone-Beam Phantom After Image Reconstruction3.2 CT Reconstruction of the Hand Section of the Human Body; 3.2.1 Assesment of the Image Quality of CT Hand Section Before Reconstruction; 3.2.2 Assesment of the Image Quality of Cone-Beam CT Hand Section After Reconstruction; 3.3 CT Reconstruction of the Head Section of the Human Body; 3.3.1 Assesment of the Image Quality of the CT Head Section Before Reconstruction; 3.3.2 Assesment of the Image Quality of the Cone-Beam CT Head Section After Reconstruction; 3.4 Quantization of the Artifacts.
3.4.1 Assessment of Image Resolution and Noise Quantization of the Artifacts3.4.1.1 Factors Affecting the Assessment of Image Resolution and Noise Quantization of the Artifacts; 3.4.1.2 Image Quality Metrics; 3.4.1.3 Computational Efficiency Measurement; 4 Visual Quality Improvement of CT Image Reconstruction with Quantitative Measures; 4.1 Existing System; 4.1.1 Background; 4.1.2 Criterion for Filtering Edge Information; 4.2 Proposed Algorithms; 4.2.1 Model Specification; 4.2.2 Boundary-Edge Correspondence; 4.2.3 Local Intensity Clustering Property; 4.2.4 Energy Formulation.
4.2.5 Multiphase Level Set Formulation4.3 Block Diagram; 4.4 Back Projection; 4.5 Filtered Back Projection (FBP) Reconstruction; 4.6 Discrete Direct Back Projection; 4.7 Data Acquisition; 4.8 Iterative Reconstruction Algorithm; 4.9 Histogram Processing; 4.10 Bias Field; 4.11 Experimental Findings; 4.11.1 Assesment of the Image Statistics of Before Image Reconstruction of CT Knee Bone; 4.11.2 Assesment of the Image Statistics of After Image Reconstruction of CT Knee Bone; 4.12 Computational Efficiency Comparison; Bibliography.
Abstract: This book highlights the experimental investigations that have been carried out on magnetic resonance imaging and computed tomography (MRI & CT) images using state-of-the-art Computational Image processing techniques, and tabulates the statistical values wherever necessary. In a very simple and straightforward way, it explains how image processing methods are used to improve the quality of medical images and facilitate analysis. It offers a valuable resource for researchers, engineers, medical doctors and bioinformatics experts alike.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Item type Current library Collection Call number Status Date due Barcode Item holds
LIBRO-E NO PRÉSTAMO LIBRO-E NO PRÉSTAMO Madrid Digital Acceso Electrónico (UEM) Ciencias de la Salud RC78.7.D53 2017 EB (Browse shelf(Opens below)) Acceso electrónico eBook.20023910
Total holds: 0

SpringerLink Springer Engineering eBooks 2017 English+International

Incluye referencias bibliográficas

Preface; Acknowledgements; Contents; About the Authors; Abstract; 1 Introduction; 1.1 Introduction to Medical Imaging; 1.2 Medical Imaging Overview; 1.3 Molecular Imaging and Its Modalities; 1.4 Medical Image Reconstruction; 1.5 Types of Image Reconstruction; 2 Artifacts Correction in MRI Images; 2.1 Existing Methods; 2.1.1 Disadvantages of Ultra-echo Time Imaging (UTE); 2.1.2 Disadvantages of Sweep Imaging with Fourier Transform; 2.1.3 Disadvantages of Water- and Fat-suppressed Proton Projection MRI; 2.1.4 Disadvantages of ZTE Imaging Without Excitation Profile; 2.2 Implemented Method.

2.3 Process Diagram2.4 Model as an Inverse Problem; 2.5 NUFFT Operator; 2.5.1 Features of NUFFT; 2.5.2 Non-uniform FFT Algorithm; 2.6 Quadratic Phase-Modulated RF Pulse Excitation; 2.6.1 Hard RF Phase Modulation; 2.7 Excitation Profile Measurement; 2.8 Pointwise Encoding Time Reduction with Radial Acquisition (PETRA); 2.9 Iterative Partial K-Space Reconstruction; 2.10 Processing of Project; 2.11 Flow Diagram; 3 Spiral Cone-Beam CT Reconstruction; 3.1 CT Reconstruction Using the Medical Phantom Image; 3.1.1 Assessment of Image Quality of the CT Medical Phantom Image Before Reconstruction.

3.1.2 Assesment of the Image Quality of Cone-Beam Phantom After Image Reconstruction3.2 CT Reconstruction of the Hand Section of the Human Body; 3.2.1 Assesment of the Image Quality of CT Hand Section Before Reconstruction; 3.2.2 Assesment of the Image Quality of Cone-Beam CT Hand Section After Reconstruction; 3.3 CT Reconstruction of the Head Section of the Human Body; 3.3.1 Assesment of the Image Quality of the CT Head Section Before Reconstruction; 3.3.2 Assesment of the Image Quality of the Cone-Beam CT Head Section After Reconstruction; 3.4 Quantization of the Artifacts.

3.4.1 Assessment of Image Resolution and Noise Quantization of the Artifacts3.4.1.1 Factors Affecting the Assessment of Image Resolution and Noise Quantization of the Artifacts; 3.4.1.2 Image Quality Metrics; 3.4.1.3 Computational Efficiency Measurement; 4 Visual Quality Improvement of CT Image Reconstruction with Quantitative Measures; 4.1 Existing System; 4.1.1 Background; 4.1.2 Criterion for Filtering Edge Information; 4.2 Proposed Algorithms; 4.2.1 Model Specification; 4.2.2 Boundary-Edge Correspondence; 4.2.3 Local Intensity Clustering Property; 4.2.4 Energy Formulation.

4.2.5 Multiphase Level Set Formulation4.3 Block Diagram; 4.4 Back Projection; 4.5 Filtered Back Projection (FBP) Reconstruction; 4.6 Discrete Direct Back Projection; 4.7 Data Acquisition; 4.8 Iterative Reconstruction Algorithm; 4.9 Histogram Processing; 4.10 Bias Field; 4.11 Experimental Findings; 4.11.1 Assesment of the Image Statistics of Before Image Reconstruction of CT Knee Bone; 4.11.2 Assesment of the Image Statistics of After Image Reconstruction of CT Knee Bone; 4.12 Computational Efficiency Comparison; Bibliography.

This book highlights the experimental investigations that have been carried out on magnetic resonance imaging and computed tomography (MRI & CT) images using state-of-the-art Computational Image processing techniques, and tabulates the statistical values wherever necessary. In a very simple and straightforward way, it explains how image processing methods are used to improve the quality of medical images and facilitate analysis. It offers a valuable resource for researchers, engineers, medical doctors and bioinformatics experts alike.

There are no comments on this title.

to post a comment.