MARC details
| 000 -CABECERA |
| campo de control de longitud fija |
03119nam a22004095i 4500 |
| 001 - NÚMERO DE CONTROL |
| campo de control |
330871 |
| 003 - IDENTIFICADOR DEL NÚMERO DE CONTROL |
| campo de control |
ES-MaUEC |
| 005 - FECHA Y HORA DE LA ÚLTIMA TRANSACCIÓN |
| campo de control |
20230102114625.0 |
| 006 - CÓDIGOS DE INFORMACIÓN DE LONGITUD FIJA--CARACTERÍSTICAS DEL MATERIAL ADICIONAL |
| campo de control de longitud fija |
a||||fo|||| 00| 0 |
| 007 - CAMPO FIJO DE DESCRIPCIÓN FÍSICA--INFORMACIÓN GENERAL |
| campo de control de longitud fija |
cr nn nnnaamaa |
| 008 - DATOS DE LONGITUD FIJA--INFORMACIÓN GENERAL |
| campo de control de longitud fija |
210105s2021 si | s |||| 0|eng d |
| 020 ## - NÚMERO INTERNACIONAL ESTÁNDAR DEL LIBRO |
| Número Internacional Estándar del Libro |
9789811572654 |
| 024 7# - IDENTIFICADOR DE OTROS ESTÁNDARES |
| Número estándar o código |
10.1007/978-981-15-7265-4 |
| Fuente del número o código |
doi |
| 040 ## - FUENTE DE LA CATALOGACIÓN |
| Centro catalogador/agencia de origen |
ES-MaUEC |
| Lengua de catalogación |
spa |
| Centro/agencia transcriptor |
ES-MaUEC |
| Normas de descripción |
rda |
| Centro/agencia modificador |
ES-MaUEC |
| 050 #4 - SIGNATURA TOPOGRÁFICA DE LA BIBLIOTECA DEL CONGRESO |
| Número de clasificación |
RD768 |
| Número de documento/Ítem |
2021 EB |
| 100 ## - ENTRADA PRINCIPAL--NOMBRE DE PERSONA |
| Nombre de persona |
Shin, Jin Woo |
| Término indicativo de función/relación |
autor |
| Código de función/relación |
aut |
| -- |
http://id.loc.gov/vocabulary/relators/aut |
| 9 (RLIN) |
677972 |
| 245 10 - MENCIÓN DE TÍTULO |
| Título |
Spinal Epidural Balloon Decompression and Adhesiolysis |
| Mención de responsabilidad, etc. |
by Jin Woo Shin. |
| 250 ## - MENCIÓN DE EDICIÓN |
| Mención de edición |
First edition 2021 |
| 264 #1 - PRODUCCIÓN, PUBLICACIÓN, DISTRIBUCIÓN, FABRICACIÓN Y COPYRIGHT |
| Producción, publicación, distribución, fabricación y copyright |
Singapore |
| Nombre del de productor, editor, distribuidor, fabricante |
Springer International Publishing |
| Fecha de producción, publicación, distribución, fabricación o copyright |
2021 |
| 300 ## - DESCRIPCIÓN FÍSICA |
| Extensión |
1 recurso en línea (XXIX, 252 páginas) |
| Otras características físicas |
270 ilustraciones a color |
| 336 ## - TIPO DE CONTENIDO |
| Fuente |
rdacontent |
| Término de tipo de contenido |
Texto |
| Código de tipo de contenido |
txt |
| 337 ## - TIPO DE MEDIO |
| Fuente |
rdamedia |
| Nombre/término del tipo de medio |
electrónico |
| Código del tipo de medio |
c |
| 338 ## - TIPO DE SOPORTE |
| Fuente |
rdacarrier |
| Nombre/término del tipo de soporte |
recurso electrónico |
| Código del tipo de soporte |
cr |
| 347 ## - CARACTERÍSTICAS DEL ARCHIVO DIGITAL |
| Tipo de archivo |
Archivo de texto |
| Formato de codificación |
PDF |
| 505 0# - NOTA DE CONTENIDO CON FORMATO |
| Nota de contenido con formato |
Chapter 1. The concept of epidural balloon decomrpression and Adhesiolysis -- Chapter 2. The types and features of the ZiNeu catheter -- Chapter 3. Precautions and notes before the procedure -- Chapter 4. Procedures of the ZiNeu series -- Chapter 5. Procedures of the ZiNeuF seires -- Chapter 6. Procedures of the ZiNeuF03 catheter -- Chapter 7. Dura puncture -- Chapter 8. Tip for selection of catheter -- Chapter 9. Determination of procedure site according to case -- Chapter 10. Post-procedure management and prognosis -- Chapter 11. Genicular Nerve Radiofrequency Ablation. |
| 520 3# - SUMARIO, ETC. |
| Sumario, etc. |
This book introduces a new medical device, the ZiNeu catheter, and explains its use for the non-surgical interventional treatment of degenerative spinal disease, including spinal stenosis. In particular, the device can directly alleviate stenosis of the intervertebral foramen or central canal and perineural adhesions, resulting in reductions in back pain, leg pain, and neurogenic claudication. The ZiNeu device was invented by the author and the JUVENUI company.. It now has CE certification and is exportable to Europe. The book opens by explaining the concepts of epidural balloon decompression and adhesiolysis and outlining the types and features of the ZiNeu catheter. The full range of procedures using the ZiNeu series, ZiNeuF series, and the ZiNeuF03 catheter is then described and illustrated, and guidance provided on key aspects of decision making and post-procedure management. The book will be of interest to all specialists in pain management. |
| 988 ## - NOTA LOCAL 598 |
| Nota local 598 (boletines) |
Springer_Medicine_2021 |
| 650 #7 - PUNTO DE ACCESO ADICIONAL DE MATERIA--TÉRMINO DE MATERIA |
| Fuente del encabezamiento o término |
embne |
| 9 (RLIN) |
413257 |
| Término de materia o nombre geográfico como elemento de entrada |
Médula espinal |
| Subdivisión general |
Heridas y lesiones |
| 776 08 - ENTRADA/ENLACE A UN FORMATO FÍSICO ADICIONAL |
| Información de relación/Frase instructiva de referencia |
Printed edition: |
| Número Internacional Estándar del Libro |
9789811572647 |
| 776 08 - ENTRADA/ENLACE A UN FORMATO FÍSICO ADICIONAL |
| Información de relación/Frase instructiva de referencia |
Printed edition: |
| Número Internacional Estándar del Libro |
9789811572661 |
| 776 08 - ENTRADA/ENLACE A UN FORMATO FÍSICO ADICIONAL |
| Información de relación/Frase instructiva de referencia |
Printed edition: |
| Número Internacional Estándar del Libro |
9789811572678 |
| 856 40 - LOCALIZACIÓN Y ACCESO ELECTRÓNICOS |
| Identificador Uniforme del Recurso |
https://go.openathens.net/redirector/universidadeuropea.es?url=https://doi.org/10.1007/978-981-15-7265-4 |
| Nota pública |
Acceso a este recurso digital (usuarios Universidad Europea de Madrid) |
| 999 ## - NÚMEROS DE CONTROL DE SISTEMA (KOHA) |
| -- |
1 |
| 942 ## - ELEMENTOS DE PUNTO DE ACCESO ADICIONAL (KOHA) |
| Fuente del sistema de clasificación o colocación |
Library of Congress Classification |
| Tipo de ítem Koha |
LIBRO-E NO PRÉSTAMO |
| Suprimir en OPAC |
No |
| 998 ## - DATOS ESTADÍSTICOS |
| Fecha de catalogación |
03/2021 |
| Tipo de materia |
E-book |
| Catalogador |
Alfonso Dols |
| Catalogado |
Sí |